H-Glu(OEt)-OEt·HCl CAS 1118-89-4 L-Glutamic Acid Diethyl Ester Hydrochloride Purity >99.0% (HPLC) Factory

L-Glutamic Acid Diethyl Ester Hydrochloride Synonyms: H-Glu(OEt)-OEt·HCl CAS: 1118-89-4 Purity: >99.0% Appearance: White to Off-White Microcrystalline Powder Production Capacity 300 Tons per Year, High Quality Contact: Dr. Alvin Huang Mobile/Wechat/WhatsApp: +86-15026746401 E-Mail: alvin@ruifuchem.com

Products Details

Chemical Properties:

Package: Fluorinated Bottle, Aluminum foil bag, 25kg/Cardboard Drum, or according to customer's requirement. Storage Condition: Store in sealed containers at cool, dry and ventilated warehouse away from incompatible substances. Protect from light and moisture.Shanghai Ruifu Chemical Co., Ltd. is the leading manufacturer of L-Glutamic Acid Diethyl Ester Hydrochloride (H-Glu(OEt)-OEt·HCl) (CAS: 1118-89-4) with high quality. Ruifu Chemical supplys a series of amino acids and derivatives. We can provide worldwide delivery, small and bulk quantities available. Purchase H-Glu(OEt)-OEt·HCl, Please contact: alvin@ruifuchem.com
Safety Statements 24/25 
WGK Germany 
RTECS MA1252280
TSCA  Yes 
HS Code 2922499990

Description:

Safety Information:

Package & Storage:

Chemical Name L-Glutamic Acid Diethyl Ester Hydrochloride 
Synonyms H-Glu(OEt)-OEt·HCl; Diethyl L-Glutamate Hydrochloride; L-Glutamic Acid Diethyl Ester HCl 
Stock Status In Stock, Production Capacity 300 Tons per Month  
CAS Number 1118-89-4 
Molecular Formula C9H17NO4·HCl 
Molecular Weight 239.70  
Melting Point 108.0~110.0℃(lit.)
Boiling Point  262℃ at 760 mmHg
Density   1.08g/cm3
Water Solubility  Soluble in Water, Almost Transparency
Storage Temp.  Sealed in Dry, Room Temperature
COA & MSDS Available
Classification Amino Acid and Derivatives
Brand Ruifu Chemical

Advantages:

How to Purchase? Please contact Dr. Alvin Huang: sales@ruifuchem.com or alvin@ruifuchem.com  15 Years Experience? We have more than 15 years of experience in the manufacture and export of a wide range of high quality pharmaceutical intermediates or fine chemicals. Main Markets? Sell to domestic market, North America, Europe, India, Korea, Japanese, Australia, etc. Advantages? Superior quality, affordable price, professional services and technical support, fast delivery. Quality AssuranceStrict quality control system. Professional equipment for analysis include NMR, LC-MS, GC, HPLC, ICP-MS, UV, IR, OR, K.F, ROI, LOD, MP, Clarity, Solubility, Microbial limit test, etc. SamplesMost products provide free samples for quality evaluation, shipping cost should be paid by customers. Factory AuditFactory audit welcome. Please make an appointment in advance. MOQ? No MOQ. Small order is acceptable. Delivery Time? If within stock, three days delivery guaranteed. TransportationBy Express (FedEx, DHL), by Air, by Sea. Documents? After sales service: COA, MOA, ROS, MSDS, etc. can be provided. Custom SynthesisCan provide custom synthesis services to best fit your research needs. Payment TermsProforma invoice will be sent first after confirmation of order, enclosed our bank information. Payment by T/T (Telex Transfer), PayPal, Western Union, etc. 

FAQ:

Stable Supply: Maintain reasonable stock    

Professional Service: One stop purchasing service

Technical Support: Technology solution available

Custom Synthesis Service: Ranged from grams to kilos

Fast Delivery: If within stock, three days delivery guaranteed

High Quality: Established a complete quality assurance system

Application:

L-Glutamic Acid Diethyl Ester Hydrochloride (H-Glu(OEt)-OEt·HCl) is a derivative of L-Glutamic Acid, widely used in pharmaceuticals, food and cosmetics industry, nutrition supplement, biological growth promoter. H-Glu(OEt)-OEt·HCl is used as an organic synthesis intermediate and pharmaceutical intermediate. H-Glu(OEt)-OEt·HCl plays an important role in pharmaceutical field. 

Sufficient Capacity: Sufficient facilities and technicians

OEM Package: Custom package and label available

Specifications:

Items

Inspection Standards

Results

Appearance

White to Off-White Microcrystalline Powder

Conforms

Specific Rotation

+21.5°~ +22.5°(C=5, EtOH)

+22.2°(C=5, EtOH)

Melting Point

108.0~110.0℃

108-110℃

Loss on Drying

<0.50%

0.20%

Water (by K.F)

<0.50%

0.21%

300MHZ1H

Consistent

Consistent

TLC Analysis

One Spot

Eligibility

D-Isomer

<0.20%

Not Detected

Assay

>99.0%min

99.5%

Solubility in H2O

Colorless, Clear, 50 mg/mL in H2O

Pass

Conclusion

Conforms to the Enterprise Standard

Main Usage

Amino Acid Derivatives; Pharmaceutical Intermediates

www.ruifuchem.com

I. Inspection procedures 1. Melting point Digital melting point instrument is used Step 2: Content 2.1 Reagents Step 1: Formic acid 2. Glacial acetic acid 3. Perchloric acid standard titration solution (C=0.1000mol/l) 4. Crystal Violet indicator liquid: 5g/l. 2.2 Instruments and equipment 1. Beaker 150ml 2. Microburet: 10ml 2. 3 Analysis steps 2. 3. I accurately weigh about 300mg of the sample pre-dried at 105℃ for 3h, put it into a 150ml bethel, add 3ml of formic acid, add 50ml of ice acetic acid, add 2 drops of crystal violet test solution (TS-74), and titrate with 0.1mol/L perchloric acid until the green end point or until the blue completely disappears. 2. 3. 2 Calculation method X is equal to C (V1-V2) times 0.2042 / M times 100 C is the concentration of perchloric acid standard titration solution, expressed in moles per liter (mol/l). V1 is the consumed volume of perchloric acid standard titration concentrated solution in sample titration, expressed in ml (ml). Volume consumed of perchloric acid standard titration solution in V2 blank test, expressed in ml (ml) 0.2042 and 1.00ml perchloric acid standard titrated concentrated liquid phase when the quality of this product is expressed in G M The quality of the sample, expressed in grams (g). 2. 4 Correction If the room temperature difference between the titration test solution and the calibration perchloric acid standard solution exceeds 10℃, it should be re-calibrated; Otherwise, the concentration C1 of perchloric acid standard solution shall be corrected according to test (2). C2= C1/1+0.0011 (t1-t2) 1+0.0011 is the expansion coefficient of glacial acetic acid The unit of room temperature for T2 calibration of perchloric acid is Celsius (° C). The unit of room temperature in which a sample is titrated is Celsius (° C). C1 t2℃ perchloric acid standard solution concentration, in moles per liter (MOL/L) 3. Dry and weightless 3.1 Instruments: Thermostatic drying oven, 1/10,000 balance. 3.2 Procedure: Take 1-2 grams of samples (accurate to 0.5mg) and put them into a pre-dried constant-weight and weighed weighing bottle. The samples will have uniform thickness at the bottom of the weighing bottle. As for the samples, they will be dried in a (105±5℃) thermoelectric oven to the constant weight. 3.3 Calculation X is m minus m1 divided by m minus m2 times 100 Where: X- moisture content % m1 -- Weight of dry sample plus measuring bottle g m2 - Measure the mass of the bottle g m- The weight of the sample g 3.4 Points for Attention 1. Points of attention: 1. Parallel samples must be made for drying and weightlessness. One sample has two results, and the error between the two results is no more than 0.5%. 2. Weighing must be careful, accurate to 0.0001. 4 to the rotation 4.1 Principles Plane-polarized light passing through a liquid or solution of a compound containing some optical activity (that is, an optically active substance) can cause optical rotation, causing the plane of polarized light to rotate to the left or right. The number of degrees of rotation is called optical rotation. At a certain temperature (usually expressed by t, can be 20℃ or 25℃) a certain wavelength of light (yellow sodium light with D, wavelength λ 589.3nm) polarized light through each milliliter containing 1g optical activity material, the thickness of 1dm (that is, 10cm) solution when the rotation is called specific optical rotation. 4.2 Requirements The D line of sodium spectrum (589. 3 nm) was used to measure the tube length of 1dm and the temperature was 20℃. 4.3 Instruments 4.3.1 Digital autotropy (accuracy ±0.001°) 4.3.2 Electronic balance (accuracy 0.0001g). 4.4 Operation Method Take 3g of this product, accurate to 0.0001g, put it in a 100ml volumetric bottle, add ethanol to dissolve and dilute it to the scale, shake well. Rinse the measuring tube with a small amount of the liquid for several times, and then slowly inject the liquid into the measuring tube (do not make bubbles occur), place the measuring tube in the gyroscope for detection, and read the optical rotation reading for 3 times in parallel. 4.5 Calculation The specific rotation of L-glutamate Diethyl carbonate to sodium spectrum D-line at 20℃ [Alpha]D20 was calculated as follows: [ɑ] D20 = alpha/m Where: α -- average number of cubic rotation readings; m -- sample quality. 4.6 Allowable difference: The absolute difference of the same sample shall not exceed 0.02% when measured twice. 4.7 Precautions 4.7.1 Solvent should be used as blank calibration before each measurement: After measurement, calibration should be made again to determine whether zero point changes during measurement. If there are any changes, the optical rotation of the sample should be determined again. 4.7.2 The sample should be clarified after dissolution and dilution; otherwise, it should be filtered. Step 5 Appearance The product shall be White to off-white microcrystalline powder  

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours